图片展示
Search
English
  • 中文
  • English

FOLI20 FT-IR Spectrometer

    • Equipped with multiple beam inlets and detector inlets

    • Resolution: < 0.3 cm-1

    • Measurement range from MIR to NIR (12800-350cm-1)

    • Configurable with liquid nitrogen and electrically cooled MCT

  • Parameters

    • Equipped with multiple beam inlets and detector inlets

    • Resolution: < 0.3 cm-1

    • Measurement range from MIR to NIR (12800-350cm-1)

    • Configurable with liquid nitrogen and electrically cooled MCT

FOLI20  FT-IR spectrometer, capable of meeting the needs of different requirements of research and development users. FOLI20 can optional configure automatic switching of MIR/NIR sources and detectors, it has the standard spectral resolution of better than 0.3cm-1 and expandability of spectral range from MIR to NIR (12800-350cm-1). FOLI20 can accommodate different internal and external accessories. It provides researchers another FTIR spectrometer to reach a new stage.


Features:

Superior Spectral resolution:

FOLI20 has spectral resolution of better than 0.3cm-1 in whole range and it can upgrade to higher spectral resolution if required. The superior resolution is suitable for most of R&D projects.

Expandable Spectral Range:

FOLI20 FTIR spectrometer can achieve the analysis of both MIR and NIR spectral range in one device, through switching the optical element automatically. It can expand from the standard MIR spectral range (8000-350cm-1) to NIR range(12800-4000cm-1). FT-NIR owns special advantages: under general circumstances, samples can be analyzed in vials directly without diluting, due to the fact that quartz is transparent in NIR range.

High Performance Design:

FOLI20 FTIR spectrometer designs exclusively for R&D institutions. It combines easy operations, high-performance design and high-cost performance into one device. FOLI20 configures room temperature DLaTGS detector and users can choose other high sensitive detectors, such as liquid nitrogen cooled MCT, Thermo Electric Cooler MCT,LN InSb and TEC InGaAs detectors. Those detectors can provide higher sensitivity and higher energy throughput for the experiment. All detectors have dual-channel A/D and 32 bit dynamic range, and acquire the lowest electronic noise.


Optional Accessories Internal and External:

  • TGA-IR coupling Module

  • GC-IR coupling Module

  • External sample compartment, vacuum or purgeable

  • External vacuum UHV Chamber

  • 2cm to 20 meters length gas cells

  • Integrating sphere accessory

  • In-situ Transmission accessory

  • In-situ Diffuse Reflection accessory

  • ATR and specular accessory



Application:

  • Pharm & Life Science

      Protein conformation and quantification

      Quantification for Active Pharmaceutical Ingredients and excipient in water solution

  • Microorganism Identification

      Characterization for the volatility and stability of medicine combined with TGA module

  • Polymer and Chemical Products

      Detection and Characterization for the volatility and  decomposition combined with TGA module

      Monitoring reaction process in lab combined with MIR fiber probe module

  • Surface analysis

      Detection and Characterization for the Ultra-Thin film and mono-layer film

      Characterization for the erosion process

  • Material Science

      Detection of Emissivity of building materials

      Evaluation for Optical material such as Infrared windows and mirrors

      Study on black material with photoacoustic spectroscopy

  • Semiconductor Industry

      Measurement for thickness of various non-metal films

      Measurement for content of Carbon/Oxygen in silicon QC

  • Soil Analysis

      Evaluation for nutrition and organic matter in soil

      Study on the characteristic of different soil


Items

Standard Parameters

Optional Parameters

Spectral 

Resolution

0.3cm-1


Spectral 

Range

8000-350cm-1

12800-4000cm-1

Light 

Source

Ceramic SiC

tungsten lamp

Beamsplitter

KBr on Ge

Quartz, CaF2, ZnSe, etc.

Detector

Room temperature DLaTGS

LN MCT, TEC MCTLN InSb, LN Ge and TEC InGaAs etc.

Sample 

Compartment

Transmission hold 50mm x 75mm

Emission port, External compartment, External sealed UHV Chamber, etc.

Signal to 

Noise

40,000:1

Photometric Precision

0.1%T

Interferometer

High stability Cube corner interferometer

Wavenumber Accuracy

< 0.01 cm-1


Wavenumber Precision

< 0.1 cm-1

Operating 

temperature

-10°C to +40°C

Storage 

temperature

-20°C to +55°C


FOLI20 FT-IR Spectrometer
Long press to look detail
Long by picture save/share
INQUIRY

在线询盘 MORE+
  • 联系人 *

  • 手机 *

  • 描述

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

FOLI20 FT-IR Spectrometer

Consultation details
INQUIRY

在线询盘 MORE+
  • 联系人 *

  • 手机 *

  • 描述

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully
图片展示

图片展示

Contact US

 

INSA Optics

AddressRoom 105, Building 5, No. 1101, Huyi Road, Nanxiang Town, Jiading District, Shanghai, china

Phone number:021-59130260/15000590832

E-mail: info@insaoptics.com

 

Copyright@INSA Optics

 

 

 

图片展示

                       focus "INSA Optics"

添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了